Focusun direct system block ice machine adopts edge-leading refrigeration industry technology. After direct heat exchange between refrigerant and water, in 5 to 8 hours, water is frozen out into ice. By that time, PLC controls the machine automatically into ice doffing process. Direct system utilizes hot Freon to defrost ice; so the defrosting process is fast. Aluminum evaporator adopts special technique to make sure the ice conforms to food grade standards; in other words, the ice can be directly consumed. Besides saving labor work and electricity consumption, its unique modular design saves much floor area than traditional brine system block ice machine.
Model | Capacity | Refrigerant | Electricity consumption | Installment power | Operating weight | Dimension |
---|---|---|---|---|---|---|
-- | Ton/D | -- | Kw | Kw | Kg | mm |
FIB-05D | 0.5 | R22/R404A | 2.055 | 2.5 | 560 | 1500×800×1800 |
FIB-10D | 1.0 | R22/R404A | 4.850 | 6.0 | 960 | 1800×1200×2000 |
FIB-15D | 1.5 | R22/R404A | 6.940 | 8.5 | 1260 | 2800×1200×2000 |
FIB-20D | 2.0 | R22/R404A | 8.160 | 10.0 | 1460 | 2800×1400×2000 |
FIB-25D | 2.5 | R22/R404A | 9.510 | 12.0 | 1660 | 3200×1400×2000 |
FIB-30D | 3.0 | R22/R404A | 11.520 | 14.0 | 2180 | 3600×1400×2200 |
FIB-35D | 3.5 | R22/R404A | 14.850 | 18.0 | 2100 | 3600×1650×2000 |
FIB-50D | 5.0 | R22/R404A | 20.900 | 25.0 | Unit:960 | L1400×W1000×H1250 |
Evaporator:2860 | L4800×W1000×H2250 | |||||
Cooling tower:670 | Ф1380×H2170 | |||||
FIB-100D | 10.0 | R22/R404A | 33.980 | 50.0 | Unit:1680 | L1800×W1000×H1450 |
Evaporator:2860×2 | L4800×W1000×H2250 | |||||
Cooling tower:670 | Ф2000×H2410 | |||||
FIB-150D | 15.0 | R22/R404A | 59.150 | 75.0 | Unit:2160 | L2000×W1200×H1600 |
Evaporator:2860×3 | L4800×W1000×H2250 | |||||
Cooling tower:1120 | Ф2175×H2565 | |||||
FIB-200D | 20.0 | R22/R404A | 85.550 | 105.0 | Unit:2896 | L2400×W1600×H1800 |
Evaporator:2860×4 | L4800×W1000×H2250 | |||||
Cooling tower:1300 | Ф2650×H2645 | |||||
FIB-250D | 25.0 | R22/R404A | 94.050 | 120.0 | Unit:3260 | L3200×W1800×H2200 |
Evaporator:2860×5 | L4800×W1000×H2250 | |||||
Cooling tower:1630 | Ф3050×H2780 | |||||
FIB-300D | 30.0 | R22/R404A | 113.550 | 150.0 | Unit:3500 | L3000×W2000×H2200 |
Evaporator:2860×6 | L4800×W1000×H2250 | |||||
Cooling tower:2730 | Ф3300×H2785 | |||||
Standard condition: Dry ball temperature is 33 ℃ and water inlet temperature is 20℃. |